-40%

Fluke Networks Microtest OMNIScanner Cat6 Cat5e Digital Cable Analyzer

$ 382.8

Availability: 100 in stock
  • Condition: Used
  • Model: Omniscanner
  • MPN: Does Not Apply
  • Brand: MICROTEST
  • Type: Computer Cable Tester
  • All returns accepted: ReturnsNotAccepted

    Description

    This unit comes with the latest firmware and has been tested against known good standards. Batteries have recently been rebuilt prior to listing. Singlemode (SM) and Multimode (MM) adapters sold separately
    The Following Items Are Included:
    (1) Microtest OMNIScanner
    (1) Microtest OMNIRemote
    (2) FLUKE CAT6/ISO Class E channel adapters
    (2) FLUKE CAT6/ISO Class E adapters
    (1) FLUKE Mod-8 channel adapters
    (1) Fluke LinkWare Cable Management Software download link
    (2) Battery Packs newly rebuilt
    (2) AC Adapter/Chargers (not pictured)
    (1) RS232 PC Usb Interface Cable
    (1) User Manual pdf
    Includes Accessories As Listed Above!
    The OMNIScanner provides advanced certification for Cat 5/5e/6 cabling links to 300 MHz using an extendible digital platform that ensures unprecedented Level III accuracy. You can rely on the OMNIScanner to help you win any Fiber Optic Cat 6/5e/5 bids.
    OMNISCANNER is the most advanced hand-held certification and diagnostic tool for the verification of copper links. The Category 7, 6, 5E (Enhanced), 5 and ISO Class F, E, D, and C tester has an extended frequency range of 300 MHz. OMNISCANNER provides full software compliance with TIA and ISO/IEC requirements for measurement reporting and analysis (including Length, Delay, ACR, NEXT, ELFEXT, Return Loss, Resistance, PSNEXT, PSACR, PSELFEXT and Attenuation). In addition, OMNISCANNER measures Length, Delay, Impedance, and Resistance on coaxial cabling.
    OMNISCANNER’s graphical user interface consists of a backlit LCD display, quick access menus, arrow keys, and descriptive menu options that guide you through certifying or troubleshooting cabling systems. For test and certification of twisted pair cabling, the OMNISCANNER requires the OMNIREMOTE unit at the opposite end of the cabling link under test. OMNISCANNER communicates with OMNIREMOTE to obtain status and perform measurements from both ends of the link.
    Features:
    Instantly pinpoint specific connection failures with S-Bands diagnostics
    Test up to 300 MHz on class F links
    Dual-fiber, dual wavelength, Multimode & Single Mode certification with OMNIFiber Adapters
    Manufacturer-specific cable libraries pre-installed
    Easily manage and document copper and fiber links with new LinkWare software
    Certify multimode and singlemode fiber with Fluke Networks OMNIFiber Adapters.
    All of Fluke Networks OMNIFiber Adapters:
    Test two fibers at two wavelengths in a single automated operation.
    Measure fibe r length, propagation delay and optical loss.
    Provide clear PASS or FAIL indication with automated results analysis.
    Enable bi-directional testing without swapping main and remote units.
    Feature standards and fiber cable libraries for easy set-up.
    Incorporate interchangeable connector adapters for simple network connection.
    Communicate with LinkWare™ Cable Test Man agement Software.
    Quickly snap onto any OMNIScanner® series cable analyzer.
    Are ruggedly built for demanding field use.
    Test multimode fiber at 850 nm and 1300 nm with the LED-base d OMNIFiber® MM.
    Test singlemode fiber at 1310 nm and 1550 nm with the laser-based OMNIFiber® SM.
    The right adapter for the job
    Your network may contain different fiber types: multimode or singlemode. The way to
    accurately test and certify your network is with an adapter designed for the job. Fluke
    Networks offers two OMNIFiber adapters. Use the OMNIFiber MM adapter for multimode fiber. Its LED sources ensure accurate, standards-compliant results when testing multimode fiber. Use the OMNIFiber SM adapter for singlemode fiber. Its laser sources ensure accurate, standards-compliant results when testing singlemode fiber.
    Fast and easy testing
    Using an OMNIFiber adapter, OMNIScanner provides a one-button •Autotest• that measures fiber length and op tical loss on two fibers at two wavelengths in a single automated operation. The scanner then compares the results to the industry standard you select and instantly provides a clear PASS or FAIL i ndication. Test more fibers in less time with OMNIFiber.
    OMNIFiber adapters connect easily to the network. Interchangeable connector adapters permit simple network connection and straightforward reference power measurement. Interchangeable connector adapters are available in the most popular connector styles.
    Reporting made simple
    LinkWare™ Software makes it easy to manage and print the rich test data, to ensure the quality of the installation and performance. Instantly access and organize your results and create professional reports that meet new certification de mands, impress your customers and give yourself a competitive edge. Merge results for the entire network with the OptiFiber Certifying OTDR or the DSP Series cable tester.
    General Specifications
    Temperature range, operating 0° to +40° C
    Temperature range, storage -10° to +60° C
    Humidity range, operating 0 to 75% RH, non-condensing
    Humidity range, storage 0 to 95% RH, non-condensing
    Certifications CE, CSA
    Dimensions 9.00 x 9.85 x 3.94 cm (3.5 x 3.9 x 1.6 in)
    Weight 0.11 kg (0.24 lb)
    Optical transmitter
    Connector ST
    Emitter type OMNIFiber MM: LED; OMNIFiber SM: Fabry-Perot (FP) laser
    Emitter wavelengths OMNIFiber MM: 850 and 1300 nm; OMNIFiber SM: 1310 and 1550 nm
    Power output (minimum) OMNIFiber MM: -19 dBm; OMNIFiber SM: -11 dBm
    Power output stability (8 hours) +/- 0.25 dB at 23 C
    Optical receiver
    Power measurement accuracy +/- 0.25 dB at 23 C, 45% to 75% RH, -20 dBm for 850/1300/1310 nm, -10 dBm for 1550 nm
    Connector Interchangeable Connector Adapters: ST, SC, FC, universal
    Detector type InGaAs
    Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
    Power measurement range + 3 to –55 dBm
    Power measurement linearity +/- 0.25 dB at 23 C
    Length measurement OMNIFiber MM: 2000 m; OMNIFiber SM: 16000 m
    Length measurement resolution OMNIFiber MM: 1 m (1 ft); OMNIFiber SM: 1 m from 0 – 2000 m OMNIFiber SM: 2 m from 2001 – 16000 m